ArthosPico – Cobalt-Chromium Coronary Stent Implantation System

 

The World’s first Co-Cr alloy stent

 

The daily routine practice of interventional cardiology shows that 30-40% percent of the total amount of interventions are carried out in small vessels, meaning coronary arteries with diameter less than 2.7mm. Surely, this is challenging and of special demand as international recognized study trials like ISAR I and II confirmed that stents made of common stainless steel composite encounter serious problems in small vessels where a bulky stent structure interferes the haemodynamic flow.

 

The Co-Cr alloy used in ArthosPico allows cutting down the strut thickness about more than 50% percent in comparison to stainless steel, without any compromise towards radial force, giving a very flexible design. All these stent features in combination with an extraordinary flexible balloon catheter has formed an up-to-date BMS-system where even lesions of tortuous vessels are reachable. 

 

  • Strut thickness of just 0.065mm
  •  
  • Demonstrated flexibility with exquisite crossing performance in complex lesions
  •  
  • Deemed for small vessels stenting
  •  
  • Stent lengths up to 38mm for any stent diameter (2.00- 4.00mm) 
  •  
  • Smooth electro-polished surface
  •  
  • Highly biocompatible  
  •  
  • Very good clinical outcome
  •  
  • CE-marked
  •    
  • Shelf life 24months 
  •  

 

The Geometry

 Ultra-flex geometry with semi-open cell design makes manoeuvring very easy.

 Arthos Pico Detail Picture 1

 

The Crossing Profile

 The profile for the whole system (stent on catheter) is;

 

IC Small: 1.05mm (Reference: 2,75x38)

IC Large: 1.22mm (Reference:   4,0x38)

 Arthos Pico Detail Picture 2

  

The Balloon Catheter

 Benchmark testing confirmed to have a catheter with stunning flexibility performance in comparison to market leading PTCA catheter. This allows in combination with stent geometry to have an excellent deliverability even to lesions of smallest tortuous vessels. Furthermore, crossing through complex lesions is enabled by a unique balloon tip technology of evenness and softness.

 Shaft Profile: 1.95/2.7 F  (all sizes compatible with 5F space stents).

  Arthos Pico Detail Picture 3

Order Information

 

Order Number

Stent Length

Balloon Diameter

20 ICS 8 P

8 mm

2.0 mm

20 ICS 12 P

12 mm

2.0 mm

20 ICS 16 P

16 mm

2.0 mm

20 ICS 19 P

19 mm

2.0 mm

20 ICS 24 P

24 mm

2.0 mm

20 ICS 28 P

28 mm

2.0 mm

20 ICS 34 P

34 mm

2.0 mm

20 ICS 38 P

38 mm

2.0 mm

 

 

 

22 ICS 8 P

8 mm

2.25 mm

22 ICS 12 P

12 mm

2.25 mm

22 ICS 16 P

16 mm

2.25 mm

22 ICS 19 P

19 mm

2.25 mm

22 ICS 24 P

24 mm

2.25 mm

22 ICS 28 P

28 mm

2.25 mm

22 ICS 34 P

34 mm

2.25 mm

22 ICS 38 P

38 mm

2.25 mm

 

 

 

25 ICS 8 P

8 mm

2.5 mm

25 ICS 12 P

12 mm

2.5 mm

25 ICS 16 P

16 mm

2.5 mm

25 ICS 19 P

19 mm

2.5 mm

25 ICS 24 P

24 mm

2.5 mm

25 ICS 28 P

28 mm

2.5 mm

25 ICS 34 P

34 mm

2.5 mm

25 ICS 38 P

38 mm

2.5 mm

 

 

 

27 ICS 8 P

8 mm

2.75 mm

27 ICS 12 P

12 mm

2.75 mm

27 ICS 16 P

16 mm

2.75 mm

27 ICS 19 P

19 mm

2.75 mm

27 ICS 24 P

24 mm

2.75 mm

27 ICS 28 P

28 mm

2.75 mm

27 ICS 34 P

34 mm

2.75 mm

27 ICS 38 P

38 mm

2.75 mm

 

 

 

30 ICL 10 P

10 mm

3.0 mm

30 ICL 14 P

14 mm

3.0 mm

30 ICL 18 P

18 mm

3.0 mm

30 ICL 24 P

24 mm

3.0 mm

30 ICL 28 P

28 mm

3.0 mm

30 ICL 34 P

34 mm

3.0 mm

30 ICL 38 P

38 mm

3.0 mm

 

 

 

35 ICL 10 P

10 mm

3.5 mm

35 ICL 14 P

14 mm

3.5 mm

35 ICL 18 P

18 mm

3.5 mm

35 ICL 24 P

24 mm

3.5 mm

35 ICL 28 P

28 mm

3.5 mm

35 ICL 34 P

34 mm

3.5 mm

35 ICL 38 P

38 mm

3.5 mm

 

 

 

40 ICL 10 P

10 mm

4.0 mm

40 ICL 14 P

14 mm

4.0 mm

40 ICL 18 P

18 mm

4.0 mm

40 ICL 24 P

24 mm

4.0 mm

40 ICL 28 P

28 mm

4.0 mm

40 ICL 34 P

34 mm

4.0 mm

40 ICL 38 P

38 mm

4.0 mm